11 March 2021

PROMETHEAN ACTIVE BOARD PROJECTOR REPAIR

We repair all Promethean Active Board classroom projectors .

Repair and maintenance for wide range of Promethean Active Board projectors

Promethean EST-P1*, Promethean PRM-32*, Promethean PRM-45*, Promethean PRM-45A*, Promethean UST-P1*

[vc_tta_accordion active_section=”1″ collapsible_all=”true” title=”OPTOMA PROJECTOR ERROR CODES”][vc_tta_section title=”PROMETHEAN ACTIVE BOARD PROJECTOR ERROR CODES” tab_id=”1615324836700-d3e850fc-9dbc0b74-f42b”]
Error Code Messages Power LED Ready LED
Over temperature 3 blinks Off
G794 fail 4 blinks 4 blinks
T1 fail 4 blinks 5 blinks
Lamp error 5 blinks Off
Ballast over temperature 5 blinks 1 blink
Ballast short circuit in output detected 5 blinks 2 blinks
End of lamp life detected 5 blinks 3 blinks
Ballast lamp did not ignite 5 blinks 4 blinks
Lamp extinguished during normal operation 5 blinks 5 blinks
Lamp extinguished during run-up phase 5 blinks 6 blinks
Lamp memory write error 5 blinks 7 blinks
Lamp memory write buffer overflow 5 blinks 8 blinks
Lamp UART buffer overflow 5 blinks 9 blinks
Lamp current calculation error 5 blinks 10 blinks
Lamp corrupted software configuration 5 blinks 11 blinks
Lamp voltage too low 5 blinks 12 blinks
Lamp FLASH memory CRC error 5 blinks 13 blinks
Lamp EEPROM memory CRC error 5 blinks 14 blinks
Lamp EEPROM configuration does not match FLASH kernel 5 blinks 15 blinks
Buner fan 6  blinks 1 blink
Lamp fan 6 blinks 2 blinks
Power fan 6 blinks 3 blinks
DMD fan 6 blinks 4 blinks
Lamp door open 7 blinks Off
DMD error 8 blinks Off
Color wheel error 9 blinks Off
[/vc_tta_section][/vc_tta_accordion]
, , , ,